Blowers Preventive Maintenance

    A Good Maintenance Program Will Keep Your Blower in Top Running Condition.

    A newly installed blower should be checked frequently during the first month of operation, especially lubrication. Check oil level in both drive end and gear end of the blower and add oil as needed. Complete oil changes are recommended every 500 operating hours, or more frequently depending on type of oil and oil operating temperature.

    The following is recommended as a minimum maintenance program:

    DAILY

    1. Check and maintain oil level, add oil as needed.

    2. Check air filter.

    WEEKLY

    1. Clean air filter. A clogged filter can seriously affect efficiency, cause overheating, and oil usage.

    2. Check relief valve to be sure it is operating properly.

    MONTHLY

    1. Inspect entire system for leaks.

    2. Inspect condition of oil and change if necessary.

    SEMI-ANNUALLY

    1. Inspect the drive line bearings.

    2. Change oil even if 500 operating hours has not been reached.